¥ 2043.00
¥ 2043.00
¥ 2043.00
¥ 2089.00
¥ 2089.00
易卖工控网(www.ymgk.com)提供”5SHY5055L0002 3BHE019719R0101 GVC736BE101 Silicon controlled industrial control spare parts module”,产品详情:品牌/厂家:ABB +8615359293870、型号:5SHY5055L0002 3BHE019719R0101 GVC736BE101+8615359293870、成色:全新、货期:现货 1天内发货、保修:180天,更多产品详情就上易卖工控网。
Product Overview:
Bus data interface
*F-female coaxial interface form
*Supports Modicon S908 RIO fieldbus protocol, communication rate: 1.544Mbps
*Isolation voltage: instantaneous isolation voltage 5000V, continuous isolation voltage 1000V
*Terminal resistance: There is no terminal resistance inside this device. Please decide whether to connect it externally as needed
Fiber optic interface
*Fiber wavelength: multimode 850nm, 1310nm; Single mode 1310nm, 1550nm
*Transmission fiber: multi-mode 50/125um, 62.5/125um, 100/140um, single-mode 8.3/125um, 9/125um, 10/125um
*Transmission distance: multi-mode 2km, single-mode 20km, optional for further distances
*Fiber optic interface types: ST, SC, FC optional, standard ST optical interface
Power supply and protection
*Power supply: Dual power redundant input, DC (9-30V), typical DC24V, power consumption less than 1.5W, with DC1000V voltage isolation and reverse protection function, industrial terminal interface
*Relay alarm output: Fiber optic link fault alarm output, contact capacity: DC48V/1 A, industrial terminal interface
mechanical properties
*External dimensions: 136 * 106 * 54mm
*Shell: IP30 protection level, corrugated aluminum reinforced casing
*Installation method: 35mm guide rail installation
*Net weight: 800g
work environment
*Working temperature: -10 ℃~70 ℃, optional wide temperature products (-40~85 ℃)
*Storage temperature: -40 ℃~80 ℃
*Humidity: ≤ 90% (non condensing)Gross weight (g): 135,4Safety level: PL e
Safe input: 8 digital inputs
Security level (SIL/PL): SIL 3- SILCL 3- PL e - Cat four
Working temperature (° C): -10 to 55
Signal display: LED indicates working status and fault diagnosis. LED indications: input, OSSD output, reset request, and status output conditions
Safe output type: 2 OSSD PNP (at 400 mA, 24 VDC), self controlled, with short circuit, overload, and parity reverse protection functions
Connection: Removable terminal block, screw contacts
MTTFD (ISO 13849-1) Age: 30 one hundred
PFHD (IEC 61508): 6,86E-09
Safe output quantity: 2 pairs of OSSD (400 mA)
Programmable signal output: 2 PNP (100 mA)
Test output: 4
Storage temperature (° C): -20+ eighty-five
MSC connector: None
Connected to MSC bus: Yes
Start/restart output and EDM: 2
MCM casing: Yes
USB input: Yes
Packaging dimensions W x H x L (mm): 36 x 127 x 113
Power supply (VDC): 24 ± 20%
Dimensions HxWxD (mm): 108 x 22,5 x 114,5
Protection level: IP 20 shell - IP 2X terminal block
Tightening method: Guide rail fastening, in accordance with EN 50022-35 standard
Gross weight (g): 206,8
Contact information: 15359213550
Contact person: He Gong
Email: geabbdcs@gmail.com 386353502@qq.com
Official website: https://www.gyamazon.com , http://www.geabb.com
This product is a Profibus DP protocol type fieldbus redundant link module, which realizes the conversion between a single bus (M port) and dual redundant buses (A, B ports). It can convert a single cable bus to a redundant Profibus DP bus or a redundant Profibus DP bus to a single cable bus. The data received from port M is broadcasted to ports A and B, but the data from ports A or B is forwarded to port M on a first come selection basis, thereby establishing only one working path at the same time. The device monitors the communication status in real-time. When the receiver of the working port detects a bus fault, it switches to the redundant port, and vice versa. The device supports setting fixed or adaptive rates with a dial switch, and supports 10 commonly used rates on the Profibus DP bus.
This device can be directly placed after the Profibus DP master station to convert a single cable bus into a redundant bus; It can also be placed at the slave station to convert redundant buses into non redundant cables, while also having performance such as photoelectric isolation and reducing interference. The product features industrial grade design, IP30 protection level, corrugated aluminum reinforced casing, 35mm rail installation, DC (12-36V) wide power input, relay alarm output, dual power redundancy protection, and other advantages.
Performance characteristics
*Support all predetermined communication rates in standard specifications
*Support manual setting of dial switches to specific communication rates or selection of rate adaptation (all electrical interfaces must have consistent rates)
*4 dual color LED status indicator lights, bus data interface fault relay output alarm
*Lightning protection for 4000V electrical interface, 1.5 A overcurrent, 600W surge protection, industrial grade design, EMC testing certification
*DC12-36V wide redundant dual power supply with reverse protection
*IP30 protection level, corrugated aluminum reinforced casing, using standard industrial 35mm guide rail installation method
Bus data interface
*9-needle Sub_ D-socket connector, pin definition in compliance with Profibus DP protocol specifications
*Supports Profibus DP bus standard
*Signal delay (electrical port): ≤ 4Bit
*Communication speed: 9.6Kbps, 19.2 Kbps, 45.45Kbps, 93.75Kbps, 187.5Kbps, 500Kbps, 1.5Mbps, 3Mbps, 6Mbps, 12Mbps
*Equipped with 4000V lightning protection, 1.5A overcurrent protection, and 600W surge protection functions
*Terminal resistor: This device does not come with a terminal resistor, please connect it externally as needed