易卖工控网(www.ymgk.com)提供”Bently本特利 330101-00-12-10-02-05 控制器模块 现货 卡件 顺丰包邮”,产品详情:品牌/厂家:BENTLY本特利、型号:330101-00-12-10-02-05、成色:全新、货期:现货 1天内发货、保修:180天,更多产品详情就上易卖工控网。
注;本站所有产品均为特殊产品,市场价格一直波动,具体以客服报价为准,因产品为全新产品,图片并非实拍,下单前请跟客服确认型号和产品,价格等详细信息,网站内二手,全新均有销售,具体请联系客服沟通。
Notes; All products on this site are special products, and the market price has been fluctuating. The specific price is subject to the customer service quotation. Because the product is brand new, the picture is not a live shot. Before placing an order, please confirm the model, product, price and other details with the customer service. Both second-hand and brand new products are sold on the website. Please contact the customer service for specific communication.
*国外直接采购,正品行货,价格优惠,售后保修,型号齐全,优势库存。
*所有备件的质保期均为1年,经过专业测试认证。
*如果您需要订购产品超过1件,请与我们联系,我们可以为您提供折扣。
*如果您发现其他供货商为相同产品提供更为低廉的价格,我们也愿意参照其价格向您提供进一步的折扣。
*如果还有其他任何问题,请随时与我们联系。
主营:世界知名品牌的PLC 、DCS 系统备件模块,优势供应,充足库存
Foxboro(福克斯波罗):I/A Series系统,FBM全系列(现场输入/输出模块)
顺序控制、梯形逻辑控制、事故追忆处理、数模转换、输入/输出信号处理、
数据通信及处理等。
Westinghouse(西屋):1C31系列DCS系统、CPU、OVATION系统、WDPF系统、
WEStation系统备件。
Triconex(英维思):冗余容错控制系统、基于三重模件冗余(TMR)结构的现代化的容错控制器。
EMERSON(艾默生):模块、卡件、驱动器等各类备件。
XYCOM:XVME系列
Bently(本特利):3500/3300系统。
Rockwell(罗克韦尔):ICS系统。
Foreign direct procurement, genuine goods, price concessions, after-sales warranty, complete models, superior inventory.
*The warranty period of all spare parts is 1 year, which has passed the professional test certification.
*If you need to order more than one product, please contact us, and we can offer you a discount.
*If you find that other suppliers offer lower prices for the same products, we are also willing to offer you further discounts based on their prices.
*If you have any other questions, please feel free to contact us.
Main products: PLC and DCS system spare parts modules of world famous brands, competitive supply and sufficient inventory
Foxboro: I/A Series system, FBM full series (field input/output module)
Sequence control, ladder logic control, accident recall processing, digital analog conversion, input/output signal processing
Data communication and processing, etc.
Westinghouse: 1C31 series DCS system, CPU, OVATION system, WDPF system
WEStation system spare parts.
Triconex: redundant fault-tolerant control system, modern fault-tolerant controller based on triple module redundancy (TMR) structure.
EMERSON: various spare parts such as modules, cards and drives.
XYCOM: XVME series
Bently: 3500/3300 system.
Rockwell: ICS system.
ABB:PM全系列DCS系统、IGCT高压变频器系列、工业机器人备件DSQC系列、INFI 90等。
Bailey(贝利):BRC系列DCS系统等。
Allen-Bradley:1756、1785、1771、1746全系列系统等。
Yokogawa(横河):CP系列等。
Honeywell(霍尼韦尔):TK/TC/CC系统等。
Reliance(瑞恩):57C系列等。
Schneider(施耐德):140系列处理器、控制卡、电源模块等。
Modicon(莫迪康):AS系列PLC系统备件。
Siemens(西门子):6ES5/6ES7414/6ES7415/6ES7416系列PLC系统备件、
Siemens MOORE,Siemens Simatic C1,Siemens数控系统等。
Motorola(摩托罗拉):MVME 162、MVME 167、MVME1772、MVME177等系列。
XYCOM:I/O、VME板和处理器等。
GE(通用电气):IC698/IC697全系列PLC系统、模块、卡件、驱动器等各类备件。
Yaskawa(安川):伺服控制器、伺服马达、伺服驱动器。
Bosch Rexroth(博世力士乐):Indramat,I/O模块,PLC控制器,驱动模块等。
Woodward(伍德沃德):SPC阀位控制器、PEAK150数字控制器。
ABB: PM full series DCS system, IGCT high-voltage inverter series, industrial robot spare parts DSQC series, INFI 90, etc.
Bailey: BRC series DCS system, etc.
Allen Bradley: 1756, 1785, 1771, 1746 series systems, etc.
Yokogawa: CP series, etc.
Honeywell: TK/TC/CC system, etc.
Reliance: 57C series, etc.
Schneider: 140 series processor, control card, power module, etc.
Modicon: spare parts for AS series PLC system.
Siemens: 6ES5/6ES7414/6ES7415/6ES7416 series PLC system spare parts
Siemens MOORE, Siemens Simatic C1, Siemens CNC system, etc.
Motorola: MVME 162, MVME 167, MVME1772, MVME177 and other series.
XYCOM: I/O, VME board, processor, etc.
GE (General Electric): IC698/IC697 full series of PLC systems, modules, cards, drives and other spare parts.
Yaskawa: servo controller, servo motor, servo driver.
Bosch Rexroth: Indramat, I/O module, PLC controller, drive module, etc.
Woodward: SPC valve position controller, PEAK150 digital controller.
下单请联系我们:苒妮15685359870(微信同号)QQ3165088973邮箱3165088973QQ@.COM,欢迎咨询。
Please contact us to place an order: Rani 15685359870 (WeChat same number) QQ 3165088973 Email 3165088973QQ@.COM , welcome to consult.
采购美国、德国、法国、意大利等欧盟工控产品、备品备件
In order to ensure safety production and realize emergency treatment of emergency accidents, the external automatic tracking regulator is installed on the six regulator circuits. In case of control system failure, the tracking regulator is automatically switched to control the regulating valve independently of DCS; 21 main valves are equipped with emergency treatment button, which is independent of DCS to realize forced switch on the valve. 2.3. hardware configuration:
Omron C200 PLC is selected in the control station, and 9 digital modules (od211/ id212), 4 analog modules (ad003) and 3 regulating modules (pid03) are configured; The operation station adopts Dell opt gx150 computer; The engineer station adopts compa PC. The composition is as follows:
2.4. software configuration of control station:
The configuration of control station is based on the system software SSS of OMRON as the technical platform and ladder diagram as programming tool. The configuration contents are as follows:
2.4.1.allocation of PLC internal address:
I/o address distribution: the i/o address of PLC is the only one-to-one register address for data communication between PLC and field detection equipment and actuator. The allocation of i/o address is the basis for further configuration of PLC; For omron-c200, i/o address is related to the connected i/o module; The i/o address of the field equipment connected to the digital module depends on the installation position and the point number on the module. The i/o address of the field equipment connected to the analog module and PID module depends on the unit number of the i/o module (different modules shall be set with different unit numbers through the hard opening and closing of the module) and the point number on the module; For example, in the configuration of this system,the analog signal of 4-20mA output by the radar level transmitter LT-101 on site is connected to the second point of analog input module ad003 with unit number 3, the address of its configuration in PLC is ir:132; When the closed signal of valve hv120 is connected to the tenth point of the digital input module id212 installed in the second slot of the expansion rack, its configuration address in PLC is ir:01210; In this system, 142 i/o addresses are defined.