易卖工控网(www.ymgk.com)提供”AXCELIS 17219790模块备件使用方法”,产品详情:品牌/厂家:、型号:AXCELIS17219790、成色:全新、货期:现货 1天内发货、保修:180天,更多产品详情就上易卖工控网。
其中较复杂的为离子交换树脂工作段单套再生的控制,通过亿维PLC我们按如下的控制工艺实现了再生的自动化控制。并有效的监视再生是否成功,再生失败或者成功后,通过上位机WINCC的强大的通知功能,通知操作员。如果失败,设置一键复位操作。再生成功,则可以切换到正常运行模式下工作。
正常运行进水:3台泵2用1备对应两组罐;
正常运行进水时,运行模式分三类:
三个交换罐1,2,3号罐为串联运行进水,只开进出水阀,其他的都关闭。
1号罐为备用,原水进入2号罐,再到进入3号罐;为2号罐和3号罐串联运行。
1号罐,2号罐为备用;原水直接进入3号罐。
单套系统再生流程:
A、关闭进水阀门1和出水阀门4,启动反冲洗泵,反冲洗进水阀门7和反冲洗排水阀门10反冲15-30Min(可调)。
B、关反冲洗进水阀门7,启动酸洗进水阀16、反冲洗排放阀10,启动酸再生泵m,再生时间为60-80min(可调)。
C、关闭酸洗进水阀16、反冲洗排放阀10,开启置换水洗电动阀19,正排水阀22,开启反冲洗泵m,清洗30-60分钟。
D、关闭其他阀门,开启碱洗进水阀13、反冲洗排放阀10,启动碱再生泵m,再生时间为60-80min(可调)。
E、关闭碱洗进水阀13、反冲洗排放阀10,开启置换进水泵m、置换进水阀19、正排水阀22,清洗30-60分钟。
Among them, the more complex is the control of single set regeneration in the working section of ion exchange resin. Through Yiwei PLC, we have realized the automatic control of regeneration according to the following control process. It can effectively monitor whether the regeneration is successful. After the regeneration fails or succeeds, it can notify the operator through the powerful notification function of the upper computer WinCC. If it fails, set the one button reset operation. If the regeneration is successful, it can be switched to the normal operation mode.
Water inflow for normal operation: three pumps, two for use and one for standby, correspond to two groups of tanks;
During normal operation, there are three types of operation modes:
No. 1, 2 and 3 tanks of the three exchange tanks are operated in series. Only the inlet and outlet valves are opened, and the others are closed.
No. 1 tank is for standby. Raw water enters No. 2 tank and then enters No. 3 tank; Run tank 2 and tank 3 in series.
1 tank and 2 tank are standby; Raw water directly enters No. 3 tank.
Regeneration process of single system:
A. Close inlet valve 1 and outlet valve 4, start the backwash pump, backwash inlet valve 7 and backwash drain valve 10 for 15-30min (adjustable).
B. Close backwash water inlet valve 7, start acid pickling water inlet valve 16, backwash discharge valve 10, start acid regeneration pump m, and the regeneration time is 60-80min (adjustable).
C. Close pickling water inlet valve 16, backwashing discharge valve 10, open displacement water washing electric valve 19, positive drain valve 22, start backwashing pump m, and clean for 30-60 minutes.
D. Close other valves, open the alkali washing inlet valve 13 and the backwashing discharge valve 10, and start the alkali regeneration pump M. the regeneration time is 60-80min (adjustable).
E. Close the alkali washing water inlet valve 13 and the backwashing discharge valve 10, open the replacement water inlet pump m, the replacement water inlet valve 19 and the positive drainage valve 22, and clean for 30-60 minutes.